Smacna Duct Support On Roof

Hvac Duct Construction Standards

Hvac Duct Construction Standards

Smacna Verification News Ductwork Kingspan Mea India

Smacna Verification News Ductwork Kingspan Mea India

Smacna Fire Smoke Combined Dampers 1 Duct Flow Hvac

Smacna Fire Smoke Combined Dampers 1 Duct Flow Hvac

Field Installations

Field Installations

Smacna And Mastic

Smacna And Mastic

Rectangular Singlewall Duct Fittings Smc

Rectangular Singlewall Duct Fittings Smc

Rectangular Singlewall Duct Fittings Smc

Roof hvac duct supports unistrut roof support system bases roof crossover stairs crossover ramps s 5.

Smacna duct support on roof.

Where fittings of configurations not shown in the hvac dcs are shown on the contract drawings they shall be constructed as though they were therein. For all ducts between the supply fan and variable volume control boxes and 1 250 pa w g. A copper roof was used on the rebuilt old senate chamber in 1819. 140 2 70 inches rs 28 inches duct over 120 inches.

Page 2 106 the load is 146 lbs load for 70 inches x. Tip you can figure the load on a duct of half of the width using table 2 46 and then double the load. Brackets curved unistrut channel. Or less as measured from the top of the duct to the bottom of the support where.

2 500 pa w g. This support can meet nearly all height requirements above the roof surface and is approved for seismic and high wind applications. Duct over 120 inches determine the tie rod load. Solar attachment clamps for metal roofs unistrut tools hardware s 5.

If the designer does not designate pressure class for duct construction on the contract drawings the basis of compliance with the smacna hvac duct construction standards is as follows. Substrate failed early metal roofs were batten style or flat seamed until. Duct dimensions duct dimensions shown in the contract. Ducts are suspended from hangers 12 in.

Duct over 120 inches. For all other ducts of any application. Replaced in a 1900 renovation the slate roof on the white house was replaced with sheet iron in 1804 the copper roof on the old church of christ in philly lasted from the 1830s to 1967. Miro industries is excited to announce the official arrival of the latest addition to the miro product lineup the model 3 0.

Seismic supports are not required for hvac ductwork when the i p 1 0 if either of the following conditions is met for the entire duct run. The types of fittings to be used based on the designer s calculations of fitting losses i e square versus 45 entry taps conical versus straight taps etc. Information required for duct construction 1. Duct construction ductwork and supports shall conform to the hvac duct construction standards metal and flexible third edition 2005.

Sheet metal and air conditioning contractors national association 4201 lafayette center drive chantilly virginia 20151 1219 tel 703 803 2980 fax 703 803 3732. A comprehensive duct layout indicating sizes design airflows pressure class and routing of the duct system.

Caddy Pyramid Rooftop Support System

Caddy Pyramid Rooftop Support System

Hvac Duct Weight Of Hvac Duct

Hvac Duct Weight Of Hvac Duct

Duct Fabrication Specifications Duct Construction Suburban Sheet Metal Ltd Page 1 Of 43 Mailing Address P O Box 739 Kennedale Tx Pdf Free Download

Duct Fabrication Specifications Duct Construction Suburban Sheet Metal Ltd Page 1 Of 43 Mailing Address P O Box 739 Kennedale Tx Pdf Free Download

Duct Construction Standards Positive Negative 8 Th For Static Pressures Revision Submittal Data Engineering Specifications Pdf Free Download

Duct Construction Standards Positive Negative 8 Th For Static Pressures Revision Submittal Data Engineering Specifications Pdf Free Download

Source : pinterest.com